background image

DX012 Getting Started Guide 

 

AP11841 Issue 1 

 

 

 

Rear panel 

 

 

 

Vents 

Ensure good ventilation at the sides and back of the unit. Avoid 

obstruction of vents while operating. Avoid dirt or liquid ingress.

 

 

Mains power input  

Switch, IEC connector and fuse for the built-in 

universal voltage PSU. This accepts voltages from 100 to 240V AC 50/60Hz. 
Secure the cable to the plastic P-clip using a T20 screwdriver. 

 

Rack ears 

The rack ears can be reversed so the unit is mounted with the XLR connectors 

facing  the  rear  of  the  rack.  Using  a Torx  T8  driver,  remove  the  3x  M3  screws 

holding the rack ears in place on each side, reposition the rack ears as shown 

below, and secure them again using the same screws. 

 

 

 

 

Only use the M3x5mm countersunk screws provided with the unit. 

 

 

 

Alternative 

position (rear 

mounting)

 

Default 

position

 

Summary of Contents for DX012

Page 1: ... Balanced analogue XLR outputs operating at nominal 4dBu level configurable to stereo AES outputs 1 8 Use the recessed switch to choose analogue or AES digital operation Output sockets 9 12 Balanced analogue XLR outputs operating at nominal 4dBu level configurable to stereo AES outputs 9 16 Use the recessed switch to choose analogue or AES digital operation Sample Rate Global selection for sample ...

Page 2: ...ges from 100 to 240V AC 50 60Hz Secure the cable to the plastic P clip using a T20 screwdriver Rack ears The rack ears can be reversed so the unit is mounted with the XLR connectors facing the rear of the rack Using a Torx T8 driver remove the 3x M3 screws holding the rack ears in place on each side reposition the rack ears as shown below and secure them again using the same screws Only use the M3...

Page 3: ...h can provide a number of Cat6 cables suitable for use with the DX012 AH10887 A 100m drum of CAT6 cable with Neutrik EtherCon locking connectors AH10886 A 80m drum of CAT6 cable with Neutrik EtherCon locking connectors AH10885 A 50m drum of CAT6 cable with Neutrik EtherCon locking connectors AH10884 A 20m drum of CAT6 cable with Neutrik EtherCon locking connectors Contact your local A H dealer for...

Page 4: ...5kg 19 x 1 9 x 8 5 x 6 5lbs DX012 boxed 600 x 335 x 150 mm x 4 1kg 23 6 x 13 2 x 5 9 x 9lbs Read the Safety Instructions Sheet included with the product and the information printed on the panel before operating A limited one year manufacturer s warranty applies to this product the conditions of which can be found at www allen heath com legal By using this Allen Heath product and the software withi...

Reviews: