A-6
Parameter List/Record
625
TORQUE MODE
0 = ZERO TORQUE COMMAND
1 = VELOCITY REG. OUTPUT
2 = EXTERNAL TORQUE REF
3 = MIN SELECTION OF 1 & 2
4 = MAX SELECTION OF 1 & 2
626
JOG RAMP ENABLE
0 = NO RAMP USED
1 = RAMP USED
627
FLUX MODE SELECT
BIT 0 = FIELD ECONOMY ENABLE
BIT 1 = FIELD WEAKENING ENABLE
BIT 2 = EXTERNAL FEED FORWARD
BIT 3 = COUNTER EMF SELECTED
BIT 4 = CEMF HOLD
BIT 5 = CEMF RESET
BIT 6 = DISABLE FIELD LOSS DETECTION
BIT 7 = NO FLUX COMPENSATION
628
PROCESS TRIM SELECT
0 = DISABLE PROCESS TRIM
1 = SPEED TRIM
2 = TORQUE TRIM
629
MOTOR OVERLOAD SELECT
0 = OVERLOAD FUNCTION DISABLED
1 = 60 SEC TO TRIP @ 150% COOLED MTRS
2 = 60 SEC TO TRIP @ 200% COOLED MTRS
3 = 60 SEC TO TRIP @ 150% MTRS
4 = 60 SEC TO TRIP @ 200% MTRS
630
FAULT REPORT
0 = CP FAULTS
1 = VP FAULTS
631
FEEDBACK FILTER SELECT
0 = NO FILTER
1 = 35/49 RADIAN FILTER
2 = 20/40 RADIAN FILTER
632
WARNING SELECT
BIT 0 = MOTOR OVERLOAD PENDING
BIT 1 = EXCESSIVE ARM VOLTS
BIT 2 = BRIDGE OVERLOAD PENDING
633
PRESET SPEED 1
634
PRESET SPEED 2
635
PRESET SPEED 3
636
PRESET SPEED 4
637
PRESET SPEED 5
638
JOG SPEED 1
639
JOG SPEED 2
641
MOP ACCEL 1
642
MOP ACCEL 2
643
MOP ACCEL 3
644
MOP ACCEL 4
645
MOP DECEL 1
646
MOP DECEL 2
647
MOP DECEL 3
648
MOP DECEL 4
649
MOP MAX SPEED
650
MOP MIN SPEED
651
ACCEL TIME
652
MOTOR OVERLOAD SELECT
Parameter
Number
Description
Value
PLC Reference