Publication 1734-UM006B-EN-P - August 2005
Configure Modules in RSLogix 5000 Software
A-7
4.
For Filter, select the Frequency from the following, which is the
value you use to filter A/B/Z inputs when you check a
corresponding checkbox.
•
No Filter
•
50 kHz
•
5 kHz
•
500 Hz
•
50 Hz (default)
5.
Check the checkboxes for the following, which use the value
you selected for Filter.
•
Filter A
•
Filter B
•
Filter Z
6.
For Invert, check the checkbox to invert the signal at Z input, if
you selected the following for Type.
•
Counter
•
Encoder X1, Encoder X2, or Encoder X4
•
Period/Rate
7.
For Scalar, if you selected Period/Rate, choose one of the
following values.
•
1
•
2
•
4
•
8
•
16
•
32
•
64
•
128
If you apply the filter, you scale the filtered Z. The value you
chose for Scalar scales the Z signal for the following
configurations.
•
Period/Rate
•
Continuous/Rate
•
Pulse Generator
AB Drives