Operation
Chapter 4
424
After a successful program load the switch register should display octal
102077.
1.
Install the recorder as described in chapter 3.
2.
Set the baud rate switch to 9600 baud. Set the track switch to track 1
or track 2.
3.
Set the power ON/OFF switch to the ON position.
4.
Be sure the write protect tab on the data cartridge is positioned to the
left, and insert the cartridge into the recorder.
5.
Wait for the recorder to complete the repacking operation.
NOTE: If the recorder is turned off while a tape rewind operation is in
progress, the data on the tape will altered.
6.
Half the processor.
7.
Position the AMP utility or diagnostic tape on the tape reader.
Bypass the man-readable leader.
8.
Press BBL.
9.
After the tape has finished loading, position the cartridge bootstrap
program tape on the tape reader. This tape is included in 8000 UR or
8000 URZ options. Bypass the man-readable leader.
10. Press BBL.
11. Set S-Register to 1 (octal) to transfer the AMP utility program and
diagnostics to the cartridge.
12. Set the P-Register to 076000 (octal).
13. Preset PRESET.
14. Press RUN. The selected AMP or Diagnostic utility program will be
copied onto the data cartridge.
Use the following procedure to load AMP from the data cassette to the
8200.
1.
Install the recorder as described in chapter 3.
2.
Set the baud rate switch to 9600 baud. Select the track containing the
desired program.
3.
Set the power ON/OFF switch to the ON position.
Recording Series 8200 AMP or
Diagnostics Utility Programs
Load AMP From Cassette to
8200 CNC