Configuring the Scanner
3–4
Publication 2755-6.2
Select Cable Type
Important: Select the cable type before configuring the scanner. The
scanner configuration codes (and some options) for each cable type
(Synapse and AdaptaScan Pass Through) are different. Each
configuration is stored separately. The selections are:
•
Enable Synapse Cable
•
Enable AdaptaScan Pass Through Cable (default)
After configuring the scanner, you can switch between configurations by
scanning the cable selection bar code.
Select Symbologies
Scan the bar code labels for the symbologies you want the scanner to
decode. Only enable the symbologies you expect to read. The scanner
automatically discriminates between all of the following symbologies.
The only exception is that the scanner cannot discriminate between Code
39 and Code 39 Full ASCII. The scanner can read and decode the
following symbologies. All symbologies are enabled by default.
UPC-A
UPC-E
Code 39
Code 39 Full ASCII
EAN 8
EAN 13
Interleaved 2 of 5
Discrete 2 of 5
Codabar
Code 128
MSI / Plessey
Code 93
EAN 128
To enable a symbology, scan the ENABLE bar code for the symbology.
To disable a symbology, scan the DISABLE bar code.