1A
OPERATIONS
1A-13
1.15 Lift Lever Adjustment
Damage to or replacement of a trowel arm can change
the adjustment of the lift lever. This can unbalance the
trowel arms and cause the trowel to wobble during oper-
ation. To operate smoothly the lift lever on all arms must
be adjusted the same to ensure that the trowel is bal-
anced correctly. Adjust trowel arms using optional trow-
el arm jig as described below.
NOTE: Make sure that there is no pitch in the
blades before attempting to remove a
trowel arm.
1. Block up pressure plate (I) using wooden blocks
(B).
2. Remove stabilizer ring from spider assembly
(only on available models).
3. Remove blades from trowel arms.
4. Loosen hex head cap screw (A) and remove it
and the external star washer from the spider
boss.
5. Remove trowel arms from spider 5-boss with
lift levers in place.
6. Clean flats on trowel arm before placing it in
the trowel arm jig (PART# 016863).
7. For HDX600 series trowels use the medium
spacer (1-1/4 X 2-1/2) (D).
8. Insert trowel arm into trowel arm jig as shown.
9. Tighten socket head bolts (E) down on the
trowel arm to hold in place.
10. Place carriage bolts (G) on lift lever under the
trowel arm jig (F) as shown.
11. Loosen jam nut (H) and adjust the carriage bolt
so that the top of the bolt is just touching the
bottom of the trowel arm jig and tighten jam nut
(H).
12. Attach trowel arm to spider boss and blades
to arms.
13. Tighten down hex head cap screw to secure
arm in place.
14. Reattach stabilizer ring (only on available models).
F
D
E
C
F
H
G
E
D