GENERAL 

MIDI 

INFORMATION 

 

The Allen MDS-Expander™ II and MIDI-Division™ II are basically the same devise. The 
Allen MDS-Expander™ II is a stand-alone unit with finished wooden sides.  The MIDI-
Division™ II provides the same features and is installed as part of the organ in a drawer.  
For this manual they will both be referred to as the MDS-Expander™ II.  They both 
respond to MIDI note and volume change messages.  Although traditional organ 
keyboards have a range of 61 notes, many MDS-Expander™ II voices will respond to the 
total MIDI range of 128 notes.  This allows the MDS-Expander™ II to be used with MIDI 
keyboards having a greater note range than traditional organ keyboards.  Some voices 
have been limited to the range of their acoustic counterpart for authenticity.  Certain voices 
(such as PIANO) are also velocity touch-sensitive when used with a MIDI device that 
transmits velocity information.  On Allen MDS, Renaissance and some Protégé organs, 
velocity information may be sent via the organ's expression pedals.  On organs that 
feature OST™ keying, velocity information is sent via the organ's keyboards.  For more 
information on this subject, consult your organ’s specific owner's manual. 

 

 II. 

BASIC 

FACTS 

 

MDS-Expander™ II voices are analogous to organ stops.  Under the "DIV" abbreviation 
located on the front panel, for example, are listed SW, GT, PD, and CH, an indication of 
the organ division that will control the voice shown next to it.  These division abbreviations 
may be changed if the settings do not correspond to the organ that the MDS-Expander™ 
II is connected to.  See "MIDI FUNCTIONS" section of this manual for details concerning 
this procedure. 

 

A different voice may be assigned to each MDS-Expander™ II division, or more than one 
division may share the same voice. 

 

The MDS-Expander™ II memory contains 60 preset groups.  Every preset contains a 
voice selection for each MDS-Expander™ II division. 

 

Presets are selected by pressing the PRESET button.  Use the UP or DOWN button to 
move to the next or previous preset.  The PRESET button will also function in the same 
fashion as the UP button, moving to the next preset each time it is pressed.  Presets may 
also be selected from the organ's pistons.  Preset contents may be altered as explained in 
the “MODIFYING MDS-EXPANDER? II PRESETS” section of this manual. 

 

Most Allen organs have divisional MIDI couplers (stops) that when engaged allow 
transmission of MIDI messages from that particular division’s manual. Each organ division 
transmits MIDI information on a different MIDI channel. THE MIDI COUPLERS THAT 
CORRESPOND TO THE MDS-EXPANDER™ II DIVISIONS MUST BE TURNED ON 
FOR THE ORGAN TO PLAY THE MDS-EXPANDER™ II’s VOICES.  Standard MIDI 
channel settings for the MDS-Expander™ II are as follows:  SW = 1, GT = 2, PD = 3, CH = 
4.  To change these MIDI settings, consult the "MIDI FUNCTIONS" section of this manual.  
To change the organ’s MIDI settings, consult the “RESETTING THE MIDI BASE 
CHANNEL” section of the organ owner's manual or “Console Controller™ and MIDI 
Guide”. 

 

Summary of Contents for MDS-EXPANDER II

Page 1: ...AOC P N 033 0090 0 Rev 10 99 BUILT IN AMERICA FOR THE WORLD MDS EXPANDER II OWNERS MANUAL Copyright 1999 Allen Organ Company All Rights Reserved ...

Page 2: ... indication of the organ division that will control the voice shown next to it These division abbreviations may be changed if the settings do not correspond to the organ that the MDS Expander II is connected to See MIDI FUNCTIONS section of this manual for details concerning this procedure A different voice may be assigned to each MDS Expander II division or more than one division may share the sa...

Page 3: ... division voice and displays a À when tremulant is turned on Note Tremulant can be added only to voices where tremulant is appropriate IV MODIFYING A MDS EXPANDER II PRESET 1 Select desired preset press PRESET then UP or DOWN 2 Select division for modification press DIV then UP or DOWN 3 Select desired voice press VOICE then UP or DOWN 4 Set desired tremulant status select desired voice press TREM...

Page 4: ... or higher FOR ALLEN ORGANS WITH CONSOLE CONTROLLER This subject is detailed in the Console Controller and MIDI Guide that is specific to any particular Allen Organ Please use that publication for this procedure NOTE Early version Console Controllers will return to Preset P Change when the organ s power is shut off Newer version Console Controllers will retain the U P or N settings after the organ...

Page 5: ... channel of the organ also changes the channel of transmission for General Pistons For more information on this subject consult the specific Allen organ owner s manual IMPORTANT Allen MDS and Protégé organs that do not have Divisional Pistons or a Console Controller transmit MIDI information from General Pistons on MIDI Channel 1 In order to change MDS Expander II Presets from the General Pistons ...

Page 6: ... PLAY button Use the UP and DOWN buttons to move the cursor through the list of selections Press the AUTO PLAY button again to start playback of the demonstration selection or Zimbelstern as indicated by the cursor To stop the demonstration press the AUTO PLAY button once again Pressing any other front panel button after stopping the demonstration will return the to the normal playing mode XIII PO...

Page 7: ... Vox Humana 8B 99 Sub Xylophone Electric Piano 57 Hautbois 8 100 Tympani 16 Chrysoglott 58 English Horn 8 17 Chimes 59 French Horn 8 18 Cast Bells 60 Clarinet 8 19 Zimbal III 61 Tuba 8 20 Cymbale III 62 Trumpet 8 21 Mixture IV A 63 Trompette 8 22 Mixture IV B 64 Spanish Trumpet 8 23 Grand Mixture IV 65 Posthorn 8 24 Fife 1 66 Musette 16 25 Septieme 1 1 7 67 Basson 16 26 Quintflöte 1 1 3 68 Dulzian...

Reviews: