BATTERY INDICATOR LIGHT
Flashing GREEN: Enough power remaining (the light turns
steady during operation). Flashing RED: Insufficient power
remaining (the light turns steady during operation).
3.
INSERT FUEL CELL INTO NAILER.
Pull the latch and open the cell cover.
Insert the fuel cell into the nailer.
Insert the stem of fuel cell into the hole of the adapter
Close the cell cover.
Lock up the latch.
4.
Remove the finger from the trigger and press the nailer
mouth against the work surface, while pulling backward
on the feeder knob. Motor fan will start.
THE NAILER SHOULD NOT OPERATE.
5.
Separate the nailer mouth from the work surface. Next,
point the nailer mouth downward, pull the trigger and
then wait in that position for 5 seconds or longer.
If there is a burst, this means the push lever is not
replacing properly, the cylinder may not have opened
and the nailer is an anomaly.
THE NAILER WILL NOT OPERATE.
6.
Depress the nailer mouth against the work surface in
a downward position and pull the trigger.
THE NAILER SHOULD OPERATE.
()
17. TESTING THE NAILER (CONT’D)
Battery Indicator Light
Latch
Cell Cover
Fuel Cell
Fuel Cell
Stem
Stem
Adapter
Cell Cover
Do not Pull the Trigger
Nail Feeder
Depress nailer
mouth against
the work surface
Pull the