Step 2: Measure the DC voltage from the +output terminals (+ and COM1) with the DMM and key in the measured value (i.e. if
the DMM shows 9.487V then key in 9.487) followed by the “ENTER” key. The following message will then appear on
the LCD:
Step 3: Repeat step 2. Key in the measured value (i.e. if the DMM shows 29.798V then key in 29.798) followed by the “ ENTER
“ key. The following message will then appear on the LCD.
Step 4: Measure the DC current from +out terminals (+ and COM1) with the DMM and key in the value (i.e. if the DMM shows
0.728A, then key in 0.728 ) followed by the “ENTER” key. The following message will then appear on the LCD: