background image

P.02

P.03

ORIGINAL FIXING INSTRUCTIONS 

Modric 2460 surface mounted hand dryer

ORIGINAL FIXING INSTRUCTIONS 

Modric 2460 surface mounted hand dryer

Mounting instructions

The Hand Dryer must be fixed to a solid 
supporting wall. The recommended 
distance from finished floor level to 
the bottom of the unit should be as 
follows:-
•   Male washrooms 

1168mm 

•   Female washrooms 

1118mm 

•   Disabled washrooms 

1016mm 

•   Children aged 14-17 

1118mm 

•   Children aged 11-13 

1016mm 

•   Children aged 8-10 

  914mm 

•   Children aged 4-7 

  672mm

To ensure ease of installation and 
subsequent maintenance, the horizontal 
distance to any adjacent wall should be 
less than 0.2 metres.
To install follow the steps below:

1. 

Drill 7mmø x 50mm deep four 

    places using template supplied  
    to mark up position (For fitting to  
  masonary). 

2.

  Insert nylon plugs.

Wiring instructions

Always ensure that the installation 
conforms to the current edition of 
the I.E.E. wiring regulations, BS 7671 
(UK) or the appropriate standards in 
your country. Ensure that the unit is 
separately fused with a suitably rated 
fuse and that it is connected to the 
supply with a double pole isolating 
switch having a contact separation of 
at least 3mm. Care should be taken 
that single insulated conductors cannot 
come into contact with the mounting 
surface. 

3. 

Screw in screws leaving 

    approximately 5mm gap.    
  (Illustration 1).

4. 

Locate dryer assembly back plate 

    over screw heads through key hole  
    apertures. pull down against surface 
    and fully tighten screws  
  (Illustration 2).

5. 

Locate cover on back plate and  

    locate and tighten screws from  
  underneath. 

1

2

Allgood plc, 

63-83 Brearley Street, Birmingham, B19 3NT 

 

 

www.allgood.co.uk

Allgood plc, 

63-83 Brearley Street, Birmingham, B19 3NT 

 

 

www.allgood.co.uk

WARNING 

The hand dryer MUST be isolated from the power  
supply during installation or maintenance.

IMPORTANT

 

After installation or servicing, units must be checked, 
and only left when electrically and mechanically safe.