90
800383
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39. CABINET TOP
a. Front Control Washers –
(1) Unlock control panel. Refer to Figure 15,
Step “1”.
(2) Pull top of control panel away from control
cabinet far enough to allow lifting control
panel up and off the rail support of the
control cabinet, Refer to Figure 15, Step
“2”.
(3) Remove control panel away from control
cabinet as far as wires permit. Refer to
Figure 15, Step “3”.
(4) Remove two screws holding front of
cabinet top to top front edge of control
cabinet front. Refer to Figure 22.
(5) If area or space permits, lift cabinet top to a
vertical position by hinging it on the rear
hinges. Refer to Figure 23.
NOTE: To avoid damage to hinges, be sure to
support cabinet top with a small chain or something
similar. Refer to Figure 23.
(6) Remove cabinet top from washer by
removing nuts and carriage bolts holding
cabinet top and hinges to control cabinet.
Refer to Figure 24.
(7) Carefully lift cabinet top off washer and set
out of the way to prevent damage.
Figure 22
3
2
1
H201SE1A
SPEED
NUTS
SCREWS
WITH
LOCKWASHER
Figure 23
Figure 24
H221SE1A
CABINET
TOP
REAR
HINGES
WIRE, ROPE
OR CHAIN
MOTOR
CONTROL
BOARD
H044PE1A
NUT
SCREW
SCREW
NUT
CONTROL
CABINET
SECURITY
TOP PANEL
SPEED
NUT
CARRIAGE
BOLT
CARRIAGE
BOLT
CABINET
TOP