33711
69
Section 7 Test Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
57. G.E. MOTOR CHECK (High and Low Windings)
OPEN
Check blue dot (C)
to yellow dot (8).
1 to 2 Ohms high windings OK.
Manually depress centrifugal switch.
OPEN
Remove white motor wire*.
Remove “B” switch terminal.
Check from end of white wire to yellow (8).
3 to 4 Ohms.
Low windings OK.
Remove white motor wire*.
Check from pink (A) to “B”
terminal.
OPEN
Low winding defective.
Replace motor.
Set Ohmmeter to R x 1 scale
Centrifugal switch in normal position.
Check pink dot (A) to yellow dot (8).
OPEN
High winding defective.
Replace motor.
1 to 2 Ohms
High winding OK. Check
pink (A) to blue (C).
OPEN
Centrifugal switch
defective. Replace switch.
CLOSED
Centrifugal switch OK.
OPEN
Manually depress
centrifugal switch.
CLOSED
Bad switch.
Replace switch.
CLOSED.
Switch OK.
OPEN
Bad switch.
Replace switch.
* Do not confuse the white wire coming from the wire harness to the white dot on the motor switch with the white
wire coming from the motor to the “B” terminal.