33711
21
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
20. TIMER
Refer to Figure 6.
a. Remove six screws (3 on top and 3 at lower
front) holding hood assembly to control hood
rear panel and cabinet top.
b. Unscrew timer knob from timer shaft (right
hand thread), then remove timer knob skirt.
c. Remove two screws holding timer to control
hood mounting plate. Refer to Figure 7.
NOTE: DO NOT attempt to repair timer.
d. Disengage wire harness terminal block plug(s)
from timer by pressing in on movable locking
tabs (located on each side of terminal block
plug) and pulling away from timer. Refer to
Figure 7.
IMPORTANT: To avoid an open circuit, DO NOT
pull on terminal block wires when removing blocks
from timer as this could damage wires or terminal
crimping.
Before attaching wire harness terminal blocks to
timer, make sure all male terminals on timer are
straight and are capable of accepting terminals
from wire harness terminal blocks.
NOTE: When installing timer, be sure timer is
installed correctly and is securely mounted to
bracket on control hood. Refer to Figure 8.
e. The horizontal and vertical tabs on front plate
of timer must seat completely into the slots on
the control hood mounting bracket, and that the
two screws are torqued down between 12 to18
inch pounds (14 to 21 cm-kg).
Figure 7
Control Hood
Assembly
Terminal Block
Plug
Timer
Attaching
Screws
Timer
Locking
Tabs