33711
61
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
f. Connect the hose from the outer tub to the
pump and tighten hose clamp.
g. Reconnect idler spring to clip on motor
mounting bracket and helper spring into the
back hole in the mounting bracket. Refer to
Figure 51.
h. Place drive belt on motor pulley, reach around
right side of motor, starting with belt on right
side of large pulley, run belt onto large pulley.
i. Route the pressure hose as shown in Figure 31.
Then route pressure hose back up through hole
in cabinet top.
j. Reconnect the filler hose to the backflow
preventer. Refer to Figure 31.
NOTE: When installing filler hose, white line on
hose must be aligned with arrow on backflow
preventer. Refer to Figure 31. White line on hose
that connects to tub cover must be aligned with line
located on top side of outer tub cover. Refer to
Figure 31. Make sure the hose is in its natural
position (not kinked or twisted) and is parallel to the
rear edge of the washer cabinet. If it is not, loosen
hose clamp and straighten the hose.
k. Reinstall cabinet top.
IMPORTANT: When reinstalling cabinet top and
before lowering top into position, pivot outer tub
forward far enough to prevent damaging (bending)
the out-of-balance switch lever.
l. Remove control hood, reconnect pressure hose
to pressure switch. Then reinstall control hood.
m. Reinstall washer front panel.
n. Reconnect washer power cord and open water
supply valves.
NOTE: Washer must be run through a complete
cycle to make sure it is operating properly.
Figure 49
Figure 50
Pivot
Dome
Washer Base
Dome Recess
Notch
Centering
Spring
(5)