54. TO CHECK CONTINUITY THROUGH MOTOR HARNESS AND MOTOR
The items within the parentheses are also being checked along with the wires.
TP – Thermal Protector, MS – Motor Switch, SW – Start Winding, HW – High Winding, LW – Low Winding.
55. TO CHECK CONTINUITY THROUGH BASE HARNESS, CONTROL HARNESS AND TIMER FOR
MOTOR START CIRCUIT.
Timer terminals involved are shown within the parentheses.
Wires
Motor Switch
Normal
Ohm
Readings
Motor Switch
Operated Manually
Ohm
Readings
Yellow to White
Continuity (TP)
0
Continuity (TP)
0
Red to Brown
Continuity (MS, SW)
4-5
OPEN
Infinite
Pink to White
Continuity (MS, HW, TP)
1-2
Continuity (MS, LW, TP)
3-4
Blue to White
Continuity (HW, TP)
1-2
Continuity (HW, TP)
1-2
Wires
Timer Set for Spin
Timer Set for Agitation
Blue to Brown
Continuity (K & G)
OPEN
Blue to Red
OPEN
Continuity (K & F)
Red to Yellow
Continuity (F & L)
OPEN
Brown to Yellow
OPEN
Continuity (G & L)