© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Specifications and Dimensions
37
C003292ENR1
Steam Requirements
(Steam Heat Option Only)
For machines equipped with optional steam heat,
install piping in accordance with approved commercial
steam practices. Steam requirements are shown in
Table 16
.
NOTE: Failure to install supplied steam filter may
void warranty.
Hot Surfaces. Will cause severe burns.
Turn steam off and allow steam pipes,
connections and components to cool
before touching.
W505
WARNING
Steam Supply Information
40
60
80
100
125
140/175
Steam inlet connection, in. (mm)
1/2 (DN13)
1/2 (DN13)
1/2 (DN13)
1/2 (DN13)
3/4 (DN19)
3/4 (DN19)
Number of steam inlets
1
1
1
1
1
1
Recommended pressure,
psi (bar)
30 – 80
(2 – 5.5)
30 – 80
(2 – 5.5)
30 – 80
(2 – 5.5)
30 – 80
(2 – 5.5)
30 – 80
(2 – 5.5)
30 – 80
(2 – 5.5)
Maximum pressure,
psi (bar)
80
(5.5)
80
(5.5)
80
(5.5)
80
(5.5)
80
(5.5)
80
(5.5)
Table 16