Troubleshooting
4. No Cold Fill Analysis (Coin)
No Cold Fill Analysis (Coin)
YES
NO
1A
5A
NO
1A
YES
NO
YES
2A
3A
NO
YES
Inspect wire 15 and repair or
replace the wire as needed.
4A
3A
With the water turned on to the machine, during a cycle that has been programmed for a cold fill,
no cold water is filling the machine.
Replace the CF fuse.
Replace the output board.
Replace the output board.
Is the CF light
on the output board
turned on?
Test the CF
fuse with an ohm
meter. Is the CF
fuse blown?
Is there voltage
(120 Volts AC)
between the CF
terminal and the
ACN?
Is there voltage
(120 Volts AC)
between the V2
terminal and the
ACN?
Inspect the water inlet valve
and hoses. Repair or replace
the water inlet valve as
needed.