Troubleshooting
6. No Supply Fill Analysis (Coin)
No Supply Fill Analysis (Coin)
With the machine beginning
a wash step that has been
programmed with a supply,
no water is coming into a
supply compartment.
3A
2A
Replace the supply fuse.
NO
YES
Is there
voltage (120 Volts AC)
between the supply terminal
(i.e., S1 or S2) and
the ACN?
1A
2A
Replace the output board.
NO
Is there
voltage (120 Volts AC)
between the output side
of the supply fuse (i.e.,
S1 or S2) and the
ACN?
YES
NO
3A
2A
Is there
voltage (120 Volts AC)
between the input side of
the supply fuse (i.e.,
S1 or S2) and the
ACN?
YES
CHM398S