© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Design 1 Only
F8266301ENR4
20
3. No Rotation without Drive Fault
No Rotation without Drive Fault
Is there an active fault on the
inverter drive? Refer to
Inverter Drive Supplement
.
Refer to “No Rotation with Drive Fault” flowchart.
Yes
Is the belt off the
pulley or is the belt
broken?
Replace belt.
Yes
No
Is the motor
turning?
No
Check that pulleys are engaged on shafts.
Yes
Is the correct
voltage present
at the drive?
No
Trace wires back to source to find where voltage is lost.
No
Is the display
active on the
drive?
Re-check supply voltage at drive - possible dead drive.
NOTE: Contact Alliance Technical Support for further assistance.
Check power at the control transformer (TR2).
Repair wiring or replace transformer as required.
Check H13 on AP1 Output Board and J16 plug.
Verify that direction/speed output LEDs are lit and
check control inputs. Refer to
Inverter Drive
Supplement
.
Yes
No
Check for 24VAC from
H13-8 to H13-1.
Yes
Yes
No
B
A
CHM476S