F8266301ENR4
26
3. Door Fails to Unlock at End of the Cycle
Door Fails to Unlock at End of the Cycle
Is the solenoid
mechanically
bound?
Replace/adjust solenoid as necessary.
Yes
Is there
continuity through
low level water pressure
switch?
Unless the machine is rotating, the
control should open the door.
Yes
Is there water in the
machine?
No
Troubleshoot the drain.
Yes
Replace the AP1 Output Board.
No
B
A
No
CHM462S