8. Excessive Cycle Time
C
Excessive Cycle Time
Is water passing
through the drain during
fill?
Check audit data for fill and drain times.
Repair/replace drain valve as necessary.
Yes
Is the machine
slow to fill?
No
Check audit data for fill and drain times.
Check water pressure and/or check for
clogged screens in fill hoses.
Yes
Check level switch and associated hoses for
obstructions or leaks. Repair/replace as necessary.
If equipped with heat, is
it taking too long to
heat?
Troubleshoot heat output circuit. Check audit
data for heater alarm errors.
No
Yes
If VFD machine, are
there load balance
issues?
Ensure machine is loaded properly.
Yes
No
No