© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
25
9001909
Machine with Electric Heating
200-240V 3AC
200-240V 3 phase (3AC) should be connected to the
connectors “L1, L2, L3”. Refer to
.
The green/yellow grounding clamp has to be
connected to the grounding wire “PE”.
380-415V 3AC + N
380-415V 3 phase (3AC + N) has to be connected to
the connectors “L1, L2, L3”, the blue neutral to the
“N” connector. Refer to
.
The green/yellow grounding clamp has to be
connected to the grounding wire “PE”.
After electrical installation is complete, run the
machine through a test cycle and check for a clockwise
basket rotation during the extract step. If rotation is not
clockwise, disconnect the power from the machine and
have a qualified electrician reverse any 2 motor leads
at the AC drive terminal block.
Electrical Specifications
Voltage Designation
Standard
Electric Heat
Mo
del
Co
de
Vo
lta
g
e
Cy
cl
e
Phase
Wir
e
Full Lo
ad
Amp
s
Circuit
Br
eak
er
AW
G
/m
m
2
kW
Full Lo
ad
Amp
s
Circuit
Br
eak
er
AW
G
/m
m
2
kW
18
P
380-415
50/60
3
3+N+PE
Not available
21
30
10/6.0
9
Q
200-240
50/60
3
3+PE
Not available
27
30
10/6.0
9
X
200-240
50/60
1/3
2/3+PE
12
15
14/2.5
0.75
Not available
30
P
380-415
50/60
3
3+N+PE
Not available
36
40
8/10.0
18
Q
200-240
50/60
3
3+PE
Not available
49
60
6/16.0
18
X
200-240
50/60
1/3
2/3+PE
18
20
12/4.0
1.5
Not available
33
P
380-415
50/60
3
3+N+PE
18
20
12/4.0
1.5
44
50
8/10.0
18
Q
200-240
50/60
3
3+PE
18
20
12/4.0
1.5
63
70
4/25.0
18
X
200-240
50/60
1/3
2/3+PE
18
20
12/4.0
1.5
Not available
40
P
380-415
50/60
3
3+N+PE
18
20
12/4.0
1.5
44
50
8/10.0
18
Q
200-240
50/60
3
3+PE
18
20
12/4.0
1.5
63
70
4/25.0
18
X
200-240
50/60
1/3
2/3+PE
18
20
12/4.0
1.5
Not available
Table 6
Summary of Contents for CFD14C