Installation
23
F8208301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Refer to
Table 2
and
Table 3
for static and dynamic
loads on the floor or foundation.
Floor Load Data, 2 Speed Models
Specification
20
30
40
60
Static floor load, lbs. (kN)
449
(1.99)
622
(2.76)
903
(4.0)
1099
(4.9)
Static pressure, lbs.-ft.
2
(kN-m
2
)
97.8
(4.68)
101
(4.84)
118
(5.65)
120
(5.75)
Dynamic load, lbs. (kN)
374
(1.66)
495
(2.2)
898
(3.99)
1404
(6.3)
Dynamic pressure,
lbs.-ft.
2
(kN-m
2
)
165.3
(7.91)
169
(8.09)
216
(10.3)
253
(12.11)
Dynamic load frequency, Hz
8.8
7.7
8.2
7.8
Maximum moment about
machine base, lbs.-ft. (kN-m)
714
(0.97)
989
(1.34)
1926
(2.61)
3086
(4.2)
Maximum vertical load, lbs. (kN)
759
(3.37)
1038
(4.62)
1653
(7.4)
2322
(10.3)
Table 2
Floor Load Data, Variable-Speed Models
Specification
20
30
40
60
80
125
Static floor load, lbs. (kN)
482
(2.14)
624
(2.78)
923
(4.11)
1061
(4.22)
1738
(7.73)
2839
(12.6)
Static pressure, lbs.-ft.
2
(kN-m
2
)
105
(5.02)
102
(4.87)
121
(5.78)
116
(5.54)
126.9
(6.07)
177.5
(8.5)
Dynamic load, lbs. (kN)
532
(2.37)
767
(3.41)
1049
(4.67)
1514
(6.73)
3310
(14.72)
4364
(19.4)
Dynamic pressure, lbs.-ft.
2
(kN-m
2
)
207
(9.98)
214
(10.22)
238
(11.37)
261
(12.47)
350.5
(16.78)
431.5
(20.6)
Dynamic load frequency, Hz
11.5
10.7
10.2
9.6
8.95
8.1
Maximum moment about
machine base, lbs.-ft. (kN-m)
1016
(1.38)
1535
(2.08)
2252
(3.05)
3328
(4.51)
8482
(11.5)
14547
(19.7)
Maximum vertical load, lbs. (kN)
950
(4.23)
1313
(5.84)
1824
(8.11)
2394
(10.65)
4799
(21.35)
6904
(30.7)
Table 3
Summary of Contents for CHM1772C
Page 2: ......