Teachmode
The Teachmode option allows the owner to program the coin
drop to accept coins or tokens that differ from those shown Dips-
witch Setting tables. Refer to the following steps to set the coin
selector to accept the new coins or tokens.
NOTE: The steps for setting Teachmode must be fol-
lowed in the exact order shown below for the Teach-
mode to work properly.
1. Set dipswitch 8 to ON (Blocked) position.
2. Set dipswitch 15 OR dipswitch 16 to ON (Blocked) position
(only dipswitches 15 and 16 are available for new coins or to-
kens).
IMPORTANT: DO NOT set both dipswitches 15 and
16 to ON (Blocked) position at the same time.
3. Insert at least 10 different coins or tokens into the coin drop to
program the coin selector.
4. Set dipswitch selected in step 2 to OFF (Accept) position.
NOTE: A click should be heard after setting dips-
witch to OFF (Accept) position. If no click is heard,
repeat steps 2-4.
5. Set dipswitch 8 to OFF (Accept) position.
6. Wait 15 seconds before testing meter with coins or tokens.
NOTE: When setting control to accept two (2) coins,
repeat steps 1-6 for second coin.
When the teaching procedure has been completed, the coin drop
magnet will operate briefly one time to indicate the Teachmode
was successful.
If the coin or token used for the Teachmode has a signal that
overlaps the signal of an already programmed coin, the coin se-
lector magnet will operate twice briefly, indicating the new coin
or token is not stored in the drop.
Coins or tokens programmed using the Teachmode will use coin
output 2 of the drop and will give one signal for each coin or to-
ken entered into the drop. (Coin Value 2 on the electronic control
must be set to the value desired for the coin or token. Refer to the
control's Programming Manual for instructions on setting coin
values.
Setting Dipswitches
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
10
Part No. 802460R7
Summary of Contents for Electronic Coin Drop 70294101
Page 2: ......