800170
131
Section 3 Troubleshooting (NetMaster Models – Dryer Control)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT\
69. NO IR COMMUNICATION
Attempt
communication
with microwand
to the control.
Bring microwand
closer to the IR
window, aim
properly and try
communication
again.
Check the following:
- Low battery on
microwand
- Is the IR window
covered or blocked
on the control?
-If needed replace the
electronic control.
- Is the IR cup properly
attached to the
microwand?
Communication
sequence checks
out.
Check the following:
-Was IR communication
disabled by
manual programming.
Is there a response
of any kind from the
electronic control?
Does the control
respond?
Does the electronic
control display “E:OF”
or “-C-”?
No
Yes
No
Yes
“-C-”
“E:OF”
No IR Communication
Dwg. 3
DRY354S