To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
Section 4
Grounding
75. WALL RECEPTACLE POLARITY CHECK (Washer Power Cord)
Refer to
Figure 15
W011GE3A
Neutral
Side
Round
Grounding
Prong
L1
Neutral
Ground
0
V.A.C.
115±12
V.A.C.
115±12
V.A.C.
NOTE: Have a qualified
electrician check polarity of
wall receptacle. If a voltage
reading is measured other
than that illustrated, the
qualified electrician should
correct the problem.