800170
155
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
86. CONTROL PANEL OVERLAY (Metered
Models)
IMPORTANT: Due to the sensitivity of the
electronic control, careful handling is required. As a
precautionary measure, we recommend using a
ground wrist strap when handling the electronic
control. Wrist strap, cord and alligator clip are
designed to carry away any electrostatic charge
from your body and to direct charge to an available
ground. By using this static protection device,
potential electrostatic discharge problems
associated with handling of electronic control will
be minimized. Always handle electronic control by
its metal edges. If a wrist strap is not available,
touch washer while it is plugged in before handling
control to dissipate any charge.
a. Removal:
(1) Unlock control panel. Refer to
Step 1
.
(2) Pull top of control panel away from control
cabinet far enough to allow lifting control
panel up and off the rail support of the
control cabinet. Refer to
Figure 21, Step 2
.
(3) Remove control panel away from control
cabinet as far as wires permit. Refer to
Figure 21, Step 3
.
(4) Support control panel, press in on locking
tabs and unplug harness disconnect blocks
from backside of electronic controls.
NOTE: DO NOT pull on wires, instead, hold board
near appropriate disconnect block and unplug by
pulling on disconnect block and individual wire
terminals.
(5) Remove ground clip holding ground wire
to control panel.
NOTE: Refer to wiring diagram when reconnecting
wires.
(6) Squeeze locking tabs on indicator light,
then pull light out through back of panel.
.
(7) Remove four screws holding electronic
control assembly to backside of control
.
(8) Remove lock assembly from control panel.
. Remove control panel
overlay by peeling it from the control panel
assembly.
NOTE: Control panel overlay has an adhesive
backing.
b. Installation:
NOTE: Before removing protective backing from
new overlay, check fit of overlay to control panel
assembly. Refer to
. Use the lock hole in
the control panel as the locating guide.
(1) Once panel overlay is fitted to the front of
control panel frame, carefully peel
protective backing from the left end of
panel overlay and press into place.
(2) Remove rest of protective backing from
panel overlay and press overlay into place
on control panel assembly.
(3) While holding control by its metal edges,
place control in opening of control panel
and fasten control down with four screws.
.
(4) Follow wiring diagram and reconnect
wires to control.
IMPORTANT: It is important to use care when
handling the control.
(5) Reinstall control panel in control cabinet
and lock control panel.