800170
179
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
102. WASHER INNER BASKET PULLEY
a. Remove control panel. Refer to
.
b. Run belt off pulley while slowly turning pulley.
c. Remove belt from motor shaft.
d. Remove cap screw (left hand thread)
lockwasher and flat washer holding pulley to
inner basket shaft. Refer to
e. Remove pulley from shaft. Loosen setscrew, if
present.
IMPORTANT: When installing pulley, always use a
new cap screw to prevent screw from loosening
during operation.
NOTE: When installing new cap screw, apply a
thread locking compound to screw threads and
torque new cap screw to 240 minimum to 260
maximum inch pounds (27.5 to 29.7 Nm).
f. After installing belt, adjust belt tension per