186
800170
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
NOTE: When installing inner basket, first clean
shaft, then apply No. 27604P Anti-Seeze Compound
to the area of inner basket shaft that will be
contacting the front and rear bearings.
w. Remove three screws holding bearing housing
arms to outer tub.
IMPORTANT: Prior to disassembly, note the
position of the pressure hose, hose clips and
mounting plate so parts can be reinstalled in the
x. While supporting bearing housing, remove
three inner screws holding bearing housing to
.
Bearing Housing Installation –
NOTE: When installing the bearing housing, be
sure to route the pressure hose under the right arm
and attach hose and pressure hose clip to mounting
plate. Refer to
. Then route pressure hose
up to the hose mounting plate on the top arm. Refer
to
. Make sure there is no slack between
these two points.
IMPORTANT: The three arm bolts should always
be tightened first and torqued to 275 inch pounds
(31.46 Nm). Then tighten the three inner bolts and
torque to 150 inch pounds (17.16 Nm).
NOTE: If a bearing failure should occur, a new
bearing housing assembly should always be used.
The bearings and seal are not serviceable parts.
Make sure the new bearing housing seal has
lubrication in all groves before installation. If not,
lubricate seal with No. 685619 Lubricant.
a. Apply No. 27604P Anti-Seize Compound to
the area of the trunnion shaft that will be
contacting the front and rear bearings. Refer to
.
b. Apply a film of grease to area of shaft that will
be contacting the bearing housing seal. Refer to
. Make sure seal lips also are packed
with grease. Refer to
IMPORTANT: When installing inner basket, the
following steps must be taken to ensure that the seal
is properly orientated:
c. Install inner basket assembly by pushing all the
way into outer tub. Refer to
Step 1
.
d. Slightly pull out inner basket about 1/4 inch to
ensure that the bearing housing seal lips are not
,
Step 2
.
NOTE: If inner basket is pulled out more than 3/8
inch (past step on trunnion shaft), repeat Steps “c”
and “d”.
e. Fully reseat inner basket. Refer to
Step 3
.
f. Install pulley and cap screw. Be careful not to
push the shaft forward while tightening the
screw.
IMPORTANT: When installing pulley, always use a
new cap screw to prevent screw from loosening
during operation. Use a thread tap to clean old
Loctite out of pulley screw receiving hole before
installing new screw. This ensures that inner basket
and pulley properly seat.
NOTE: When installing new cap screw, apply a
thread locking compound to screw threads and
torque new cap screw to 240 minimum to 260
maximum inch pounds (27.5 to 29.7 Nm).