800170
203
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
NOTE: When replacing motor, motor switch
should be at 10 o’clock position. The positioning tab
on the motor should be engaged with the anti-
rotating notch in the motor bracket.
o.
Motor Connection Block Terminals
Remove terminals from the motor wire harness
connection block using No. 283P4 Terminal
Extractor Tool as follows:
(1) Insert the tool into the block on the back of
the terminal being removed. Refer to
(2) Apply tool pressure to compress the
terminal locking tab on terminal and force
the terminal and wire out back side of
connection block. Refer to
To install terminal in connection block, insert
terminal (with wire securely crimped in place)
into back side of connection block. Push
terminal into connection block until locking tab
on terminal spreads and holds terminal in place.
Figure 68
Connection
Block
283P4
Terminal
Extractor
Tool
Terminal
Locking
Tab
D251SE3A