800170
233
Section 7 Dryer Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
146. THERMAL FUSE (Electric Models)
a. While supporting the access panel, remove two
screws from bottom edge of front access panel.
.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
.
c. Label and disconnect wires from thermal fuse.
.
NOTE: Refer to wiring diagram when rewiring
thermal fuse.
d. Set multimeter to read Ohms. Apply meter
probes to thermal fuse terminals. Multimeter
should read 0 Ohms. If the meter does not show
any reading (infinite Ohms), then the fuse is
open. If the fuse is open, then replace BOTH
the thermal fuse and the limit thermostat.
147. HEATER ASSEMBLY (Electric Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to
.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
.
c. Disconnect wires from heater assembly. Refer
to
.
NOTE: Refer to wiring diagram when rewiring
heater assembly.
d. Set meter to read Ohms. Apply meter probes to
the heater assembly terminals. Meter should
read as follows: (Cold Ohms). Refer to
.
148. CYCLING OR LIMIT THERMOSTAT
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
.
c. Label and disconnect wires from thermostat.
.
NOTE: Refer to wiring diagram when rewiring
thermostat.
Cycling Thermostat (S.P.S.T. – 2 Terminals)
or Limit Thermostat
a. Set meter to read Ohms.
(1) Apply meter probes to the thermostat
terminals.
(2) Meter should read “zero.”
Element
Color
Code
KW
Voltage/Hz.
Resistance Reading
Red
5
240 V 60 Hz. 10.39 ± .31 Ohms Cold
White
4.75 208 V 60 Hz. 8.2 ± .5 Ohms Cold
Green
4.8
240 V 50 Hz. 10.75 ± .32 Ohms Cold
Yellow
4
240 V 50 Hz. 13.03 ± .39 Ohms Cold
Blue
3.1
240 V 50 Hz. 16.7 ± .5 Ohms Cold
Orange
5.35 240 V 60 Hz. 9.72 ± .3 Ohms Cold
Purple
4.25 208 V 60 Hz. 9.27 ± .3 Ohms Cold