To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
Troubleshooting
MDC Models – Dryer Control
60. ERROR CODE LISTING
OP
Open Thermistor
Error.
This error code indicates a physical open in the thermistor circuit.
Possible causes are: 1) thermistor, 2) wiring between control and
thermistor, or 3) control.
SH
Shorted Thermistor
Error
This error code indicates a short in the thermistor circuit. Possible
causes are: 1) Shorted thermistor, 2) a short in the wiring between
control and thermistor, or 3) control.
EC:19
(Card Reader
Machines)
No Card Reader
Communication
This error code indicates there is no card reader communication.The
control and the reader cannot communicate. Check reader, control
and harness.
NOTE: For all other Card Reader errors, consult the Card
Reader manufacturer.