Section 3 Troubleshooting (MDC Models – Dryer Control)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
61. COINS IGNORED WHEN ENTERED
Does the
display on the
electronic control
increment
properly?
Is
connector H5 on the
control firmly seated in
its receptacle?
Is the
3 pin connector
between the coin drop
and the control
connected
correctly?
Are
wires exiting
coin drop optical
sensor cracked
or broken?
Start coin drop
diagnostic test.
Refer to Production
Test Cycle section of
Programming manual.
Replace coin drop.
If problem still exists
replace the control.
Exit diagnostic
testing and reset
control (prompting
for vend price).
Reconnect and
run diagnostic
test again.
Replace
electronic
control.
Coins Ignored When Entered
Dwg. 2
DRY353_S
YES
NO
NO
NO
NO
YES
YES
YES