154
800170
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
85. ELECTRONIC CONTROL (Metered Models)
IMPORTANT: Due to the sensitivity of the
electronic control, careful handling is required. As a
precautionary measure, we recommend using a
ground wrist strap when handling the electronic
control. Wrist strap, cord and alligator clip are
designed to carry away any electrostatic charge
from your body and to direct charge to an available
ground. By using this static protection device,
potential electrostatic discharge problems
associated with handling of electronic control will
be minimized. Always handle electronic control by
its metal edges. If a wrist strap is not available,
touch washer while it is plugged in before handling
control to dissipate any charge.
NOTE: New control is supplied in a special anti-
static wrapping, and protected by anti-static foam.
While holding control by its metal edges, remove
control from foam and wrapping.
a. Unlock control panel. Refer to
Figure 21, Step
1
.
b. Pull top of control panel away from control
cabinet far enough to allow lifting control panel
up and off the rail support of the control
Figure 21, Step 2
.
c. Remove control panel away from control
cabinet as far as wires permit. Refer to
Figure 21, Step 3
.
d. While supporting control panel, press in on
locking tabs and unplug harness disconnect
blocks from backside of electronic control.
e. Remove ground clip holding ground wire to
control panel.
NOTE: DO NOT pull on wires, instead, hold board
near appropriate disconnect block and unplug by
pulling on disconnect block and individual wire
terminals.
NOTE: Refer to wiring diagram when reconnecting
wires.
f. Remove four screws holding electronic control
assembly to backside of control panel. Refer to
.
g. Place the old control in the anti-static wrapping
that the new control was supplied in.
h. While holding new control by its metal edges,
place control in opening of control panel and
fasten control down with four screws removed
in Step “e”. Refer to
NOTE: For proper control alignment, tighten the
top two screws first then tighten the bottom screws.
.
i. Follow wiring diagram and reconnect wires to
new control.
IMPORTANT: It is important to take care when
handling the original control. It must be carefully
placed in the anti-static wrapping and anti-static
foam which was removed from new control. If
control is not wrapped properly, warranty credit
will not be issued.