166
800170
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
93. ELECTRIC DRAIN PUMP
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
IMPORTANT: There will always be some water
that will remain in the pump and hoses, therefore,
before removing hoses from pump, hoses must be
drained to prevent water spillage.
c. Loosen hose clamps and remove three hoses
connected to electric drain pump (outer tub-to-
pump hose, vent hose and drain hose). Refer to
.
d. Disconnect wires from drain pump.
NOTE: Refer to wring diagram when rewiring
drain pump.
e. Remove three mounting screws holding pump
to base and remove pump out through front of
.
Figure 32
H112SE1A
Mounting
Screw
Electric
Drain
Pump
Drain
Hose
Backflow
Preventer
Outer-Tub-To
Pump Hose
Mounting
Screws
Vent
Hose