800170
167
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
94. WASHER BELT
a. Go to rear of washer and remove two screws
holding rear access panel to rear of control
.
b. Tilt access panel back far enough to disengage
bottom of access panel from opening in control
cabinet.
c. Reach in through opening and remove screw
holding service door to control shield and
remove service door. Refer to
d. Remove screws holding lower rear access panel
to rear panel and remove access panel. Refer to
.
e. Run belt off cylinder pulley while slowly
.
f. Remove belt from motor shaft.
NOTE: When installing belt, adjust belt tension per
Figure 33
Com
me
rcia
l W
ash
er / D
rye
r
W
AS
HE
R
DR
YE
R
H164SE3A
Belt
Access
From
Above
Belt
Access
From
Below
Cylinder
Pulley
Rear
Access
Panel
Motor