200
800170
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
IMPORTANT: When installing lint filter, be sure to
install the filter with the words facing the front of
the dryer. If filter is installed backwards, lint will
accumulate in exhaust system, which can adversely
affect dryer performance.
c. Remove three screws holding the air duct to the
front bulkhead inside cylinder. Refer to
.
d. Carefully lift air duct out of dryer.
IMPORTANT: When reassembling, be sure seal on
exhaust fan cover makes airtight seal on flange of
duct. Refer to
. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted which can adversely affect dryer
performance.
123. DRYER MOTOR AND EXHAUST
ASSEMBLY
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
.
c. Open loading door, remove screw, and lift filter
out of bulkhead.
d. Remove screws holding air duct to front
bulkhead (inside cylinder). Refer to
.
IMPORTANT: When reassembling, be sure seal on
exhaust fan cover makes airtight seal on flange of
. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted, which can adversely affect dryer
performance.
e. Disconnect wires from thermistor.
NOTE: Refer to wiring diagram when rewiring
thermistor.
f. Remove screw holding ground wire to dryer
base. Refer to
g. Remove cylinder belt from idler and motor
pulleys. Refer to
h. Disengage motor wire harness terminal block
from motor switch by pressing in on the
movable locking tabs (located on each end of
the terminal block) and pulling away from
motor. Refer to
.
i. Remove two screws holding motor mounting
bracket to dryer base. Refer to
.
Figure 63
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
WARNING
Cover
Attaching
Screws
Ground
Wire
Thermistor
Motor
Mount
Attaching
Screws
D325SE3C
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
WARNING