800170
219
Section 6 Adjustments
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer/dryer before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start the washer/dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer/dryer is properly grounded.
W014R1
WARNING
136. BURNER FLAME (Gas Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to
.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to
.
c. Set timer at “60” minutes (nonmetered) or add
coins (metered).
d. Close the loading door. Start the dryer in a heat
setting (refer to Operating Instructions supplied
with the dryer). The dryer will start, the igniter
will glow red, and the main burner will ignite.
e. Allow the dryer to operate for approximately
five minutes, then loosen the air shutter
.
f. Turn the air shutter to the left to get a luminous
yellow tipped flame, then turn it back slowly to
the right to obtain a steady blue flame.
g. After proper flame is obtained, tighten air
shutter lockscrew firmly. Refer to
.
h. Reinstall access panel and screws.
After the dryer has operated for approximately three
minutes, exhaust air or exhaust pipe should be warm.
To reduce the risk of fire or serious injury,
the access panel must be in place during
normal operation.
W262
WARNING
Figure 83
Air
S
hutter
Lock
s
crew
Air
S
hutter
S
hut-Off Valve
Handle
1/
8
Inch Pipe Plu
g
(For checkin
g
manifold pre
ss
ure)
D265
S
E
3
A