801683
89
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
38. NON-ELECTRONIC COIN DROP
Front Control Washers
a. Removal:
(1) Unlock control panel. Refer to
Step “1”
.
(2) Pull top of control panel away from control
cabinet far enough to allow lifting control
panel up and off the rail support of the
control cabinet front. Refer to
Step “2”
.
(3) Remove control panel away from control
cabinet as far as wires permit. Refer to
Figure 14, Step “3”
.
(4) Remove two screws holding front of
cabinet top to top front edge of control
cabinet front. Refer to
.
(5) If area or space permits, lift cabinet top to a
vertical position by hinging it on the rear
hinges.
NOTE: To avoid damage to hinges, be sure to
support cabinet top with a small chain or something
similar. Refer to Figure 23.
(6) Disconnect coin drop harness at disconnect
block.
(7) Use a 3/8 inch square drive socket, with
number 310P4–quarter inch Ratchet
Extension Tool, to remove two locknuts
holding coin drop to front of control
cabinet.
NOTE: A 3/8 inch square drive socket, size 7/16
inch, fits over end of the 310P4 Extension Tool. A
1/4 inch ratchet fits in the other end. Refer to
Figure 33.
(8) Lift back end of coin drop and pull drop
straight back until front edge of the drop’s
front face plate clears the two guide wires.
(9) Carefully slide drop straight back until drop
clears inside wall of control cabinet.
Carefully remove drop out through top of
control cabinet.
b. Installation:
(1) Lift coin drop up on coin drawer housing.
(2) Line up holes in the front face plate of coin
drop with the two guide wires. Slide coin
drop forward, making sure guide wires are
through holes in front face plate of coin
drop.
(3) Slide coin drop forward all the way until
front face plate of coin drop is up against
the control cabinet front, with the coin
return stop completely through slot.
(4) Using a 3/8 inch square drive 7/16 inch
socket with number 310P4 1/4 inch Ratchet
Extension Tool, reinstall both locknuts and
tighten locknuts firmly.
(5) Reconnect coin drop wire harness.
(6) Lower cabinet top into position and
reinstall two screws (previously removed)
holding cabinet top to top front edge of
control cabinet front. Refer to
(7) Reinstall control panel in control cabinet
and lock control panel.
Rear Control Washers
a. Removal:
(1) Unlock and open service door.
NOTE: If screw type lock is used, the retainer
bracket must be removed from inside meter case.
(2) Disconnect wire harness from coin drawer
switch and disconnect coin drop at
disconnect plugs.
(3) Press in on locking tabs of service door
switch and remove switch from bracket on
meter case, as shown in
.
(4) Press in on locking tabs of coin drawer
switch and remove switch through front of
meter case. Refer to
.
(5) Use a 7/16 inch socket with No. 310P4 1/4
inch Ratchet Extension Tool and remove
two locknuts holding coin drop to front of
meter case.Refer to
Summary of Contents for HWFB61QN1102
Page 2: ......