801683
117
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
o. Remove nut, washers and screw holding clamp
ring to outer tub front panel. Refer to
.
p. Remove rubber seal from outer tub front panel
and discard seal.
IMPORTANT: Always replace outer tub seal with a
new seal. Spray or apply a mixture of diluted
laundry detergent to assist in installation of new
seal. The “puffy” side of seal should be installed to
the inside. For best results, tap clamp ring all
around while tightening screw and nut.
NOTE: Install clamp ring by placing clamp ring
opening at approximately the 10 o’clock position to
ensure that no interference is encountered with side
panel or the underside of the control cabinet or
cabinet top. Tighten the clamp ring screw and nut
until a spacing of one inch is achieved at the clamp
ring opening or until tight.
57. INNER BASKET PULLEY
a. While supporting lower front access panel,
remove two screws from bottom edge of panel
and remove panel. Refer to
.
b. Using the special tool, No. 318P4, remove
dispenser drawer. Refer to
.
c.
Front Control Washer –
(1) Remove control panel. Refer to
.
(2) Remove two screws holding front of
cabinet top to top front edge of control
cabinet front. Refer to
Rear Control Washers –
(1) Unlock and remove meter case service
door. Refer to
.
(2) Remove shoulder screw from inside meter
case. Refer to
(3) Remove security bolt (if present) from left
rear corner of cabinet top. Refer to
.
d. While supporting the front panel assembly,
remove the two bottom front corner screws.
Refer to
. Remove front panel (with
loading door attached) away from washer as far
as wires permit.
e. Unplug wire harness from both the door latch
switch and from the door switch. Refer to
. Remove clips holding wire harness
and door seal hose along top flange of front
panel and remove front panel.
NOTE: The large wire clip holds both the wire
harnesses and the door seal hose. Refer to
Figure 48.
f.
Rear Control Washers –
Remove two screws
holding cabinet top to front flange of side
panels. Refer to
.
g. If area or space permits, lift cabinet top to a
vertical position by hinging it on the rear
hinges.
NOTE: To avoid hinge damage, be sure to support
cabinet top with a small chain or something similar.
Refer to Figure 23.
Figure 51
FLW1116
S
Ground
Wire
Outer Tub
Front Panel
Screw
Washers
Nut
Seal
Clamp
Ring
Summary of Contents for HWFB61QN1102
Page 2: ......