70
801683
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
31. CONTROL PANEL (Rear Control Washers)
Electronic Control Models
IMPORTANT: Due to the sensitivity of the
electronic control, careful handling is required. As a
precautionary measure, we recommend using a
ground wrist strap when handling the electronic
control. Wrist strap, cord and alligator clip are
designed to carry away any electrostatic charge
from your body and to direct charge to an available
ground. By using this static protection device,
potential electrostatic discharge problems
associated with handling of electronic control will
be minimized. Always handle electronic control by
its metal edges. If a wrist strap is not available,
touch washer while it is plugged in before handling
control to dissipate any charge.
a. Remove two control panel attaching screws.
. Lay assembly forward on
protective pad on cabinet top.
b. Disconnect all wires and harness connectors
from electronic control.
NOTE: DO NOT pull on wires. Instead, hold board
near appropriate disconnect block and unplug by
pulling on disconnect block.
c. Remove ground clip holding ground wire to
control panel.
NOTE: Refer to wiring diagram when reconnecting
wires.
d. Remove panel.
Electromechanical Models
a. Remove two control panel attaching screws
holding control panel to control hood. Refer to
. Lay assembly forward on protective
padding on cabinet top.
b. While supporting control panel, disconnect all
wires from control panel components. DO NOT
pull on wires.
NOTE: Refer to wiring diagram when reconnecting
wires.
c. Loosen setscrews holding switch knobs to
temperature and motor switch shafts and pull
knobs off switch shafts. Refer to
d. Remove nuts holding temperature and motor
switches to control panel and remove switches.
Refer to
.
e. Remove nut holding push-to-start switch to
control panel and remove switch. Refer to
.
f. Squeeze together locking tabs holding indicator
light(s) to control panel and pull light out rear
of control panel. Refer to
g. Remove ground clip holding ground wire to
control panel.
h.
Motor Speed Switch or Wash Temperature
Switch
:
(1) Remove two control panel attaching
. Lay assembly
forward on protective pad on cabinet top.
Figure 15
Protective
Padding
Control
Panel
Control Panel
Attaching
Screws
FLW1739S
Summary of Contents for HWFB61QN1102