Specification
Model
Requirement
Average flow rate of draining gal/min. [l/
min.]
All
55.48 [210]
Drain pump with hose - internal diameter
of hose, in [mm]
7 kg - 8 kg /
14 lb. - 20 lb. /
65 L - 80 L
0.75 [19]
Flow rate of drain pump, gal/min. [l/
min.]
7 kg - 8 kg /
14 lb. - 20 lb. /
65 L - 80 L
9.51 [36]
Table 4
The main drain channel-pipe must have the capacity to be able to
handle the total output of all connected machines. In a drainpipe,
a vent must be provided every 65.62 ft. [20 m] to assure the drain
pipe will work. If the main drain pipe cannot be sufficiently ven-
ted, install a vent per machine. Every time a machine is coupled
on the drainpipe, the diameter of the tube or the width of the
waste channel must increase. Refer to
Figure 11
.
The diameters of drain pipe for machines with two drain valves
must have dimensions suitable for double the value of water flow.
CHM2481N_SVG
2
C
B
A
1
1.
Vent
2.
Flow
Figure 11
Drain Line Sizing / Minimum Drain ID, in. [mm]
A - 1 Machine
B - 2 Machines
C - 3 Machines
3 [75]
4 [100]
5 [125]
Table 5
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
24
Part No. D1625ENR4
Summary of Contents for IYU180J