28 kg / 70 lb. / 280 L Models
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
CSA
AWG
(mm
2
)
X
200-240
60
1/3
2 (L1, L2 or
L1, N)
16
20
14 (2.5)
N
440-480
60
3
3 (L1, L2,
L3)
7.2
10
14 (2.5)
Table 26
Steam Requirements (Steam Heat Op-
tion Only)
WARNING
Hot Surfaces. Will cause severe burns. Turn steam
off and allow steam pipes, connections and compo-
nents to cool before touching.
W505
For machines equipped with optional steam heat, install piping in
accordance with approved commercial steam practices. Steam re-
quirements are shown in
Table 27
.
Specification
Requirement
Steam inlet connection size,
in. BSP
1/2"
Steam pressure, PSI [bar]
15-116 [1-8]
Table 27
IMPORTANT: It is necessary to insert a filter with per-
meability up to 0.0118 in. [300 µm] in front of the steam
valve. Dirt larger than 0.0118 in. [300 µm] may damage
the steam valve and cause leaks.
IMPORTANT: Failure to install the customer supplied
steam filter may void the warranty.
Use an inlet steam pressure hose only adapted to the steam valve
with appropriate seal suitable for the applied working pressure.
Steam Valve Installation
1.
Remove the rear cover.
2.
Fit the bracket with the steam valve and filter onto the rear
part of machine.
CHM2483N_SVG
4
3
2
1
1.
Bracket
2.
Steam hose
3.
Cable
4.
Steam coil
Figure 30
3.
Connect steam hose to steam valve.
4.
Connect the cable to the steam coil.
5.
Fit rear cover back to its original place.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
46
Part No. D1625ENR4