Electrical Connection of External Liq-
uid Soap Supply System
The power supply of the external liquid soap supply syste has to
be connected to an external electrical source. Only authorized
workers with valid qualifications must execute the electrical con-
nection on the machine according to valid local standards. The
correction connection can be found on the wiring diagram inclu-
ded with the machine. Do not connect the liquid soap pump sys-
tem in the washer.
The electric connection for supply control signals is available on
the rear panel. Refer to
Figure 31
. At the terminal box, there is a
label for electric connection. Detail on connection of signals can
also be found on the electric scheme of the machine.
CFD3113N
Figure 32
Signals for supply pump control are 24 VAC. Maximum current
for control circuits of pump must be limited to 100mA. Lead the
cable for connetion of pump control signals through the plastic
cable bushing. After connection of conductors to the respective
positions of the connector "P", fix up the cable by tightening the
cable bushing against disconnections and close the box with the
cover. For details about liquid soap supply sytem programming,
refer to Programming Manual.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
48
Part No. D1625ENR4
Summary of Contents for IYU180J