32
801805
Section 3 Troubleshooting (Washer Control)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
24. WASHER WILL NOT FILL – NO COMMUNICATION ERROR
(WASH/DOOR LEDS FLASHING)
Is there
220-240 VAC (or
120 Volts)* at terminals
"H9-4" and "H1-1" on the
motor control
board?
Replace
pressure
switch.
No
No
Is there
220-240 VAC (or
120 Volts)* at terminals
"H9-1" to "H1-1" on the
motor control
board?
Yes
(1)
(2)
(3)
Yes
Replace
pressure
switch.
Correct wiring
between machine
control and
pressure switch.
Yes
No
No
Replace
motor
control.
Replace mixing
valve.
(4)
Is there
220-240 VAC
(or 120 Volts)*
at the
mixing valve?
Is there
220-240 VAC (or
120 Volts)* between
the BRN/YEL wire on the
pressure switch and
"H6-5" on machine
control?
Is the door
locked?
Refer to section:
Washer Will Not Start -
No Door Lock .
No
Yes
Yes
FLW1730S
*Refer to machine serial plate
for correct voltage.