801805
59
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
42. MIXING VALVE
NOTE: Mixing valve is located on upper back right
corner of rear panel. Refer to Figure 12.
a. Shut off external hot and cold water supply and
remove two inlet hoses.
b. Go to rear of washer and remove screw holding
mixing valve and plate to rear panel, then
remove valve and plate out through opening in
rear panel. Refer to Figure 12.
c. Remove screws holding valve to mixing valve
d. Loosen hose clamp and remove mixing valve-
to-dispenser hose at the mixing valve. Refer to
Figure 12.
e. Remove wire harness disconnect blocks from
mixing valve solenoid terminals. Refer to
Figure 12.
NOTE: Refer to wiring diagram when rewiring
solenoids.
Figure 12
H165SE3B
Mixing Valve-To-
Dispenser Hose
Hose
Clamp
Inlet
Hose
Screws
Mixing
Valve
Plate
Wire Harness
Disconnect
Blocks
Mixing
Valve