2.   Install standpipe adapter onto drain hose only if standpipe di-

ameter is 2 inches [51 mm] or less.

3.   Place the drain hose into the standpipe.

IMPORTANT: To prevent siphoning, do not place
any ribbed portion of the drain hose into the stand-
pipe.

4.   Remove the beaded strap from accessories bag and place

around standpipe and drain hose, approximately 12 inches
[300 mm] down from the top of pipe. Refer to 

Figure 5 

.

a.   Insert the end of the beaded strap into the larger hole

found on the end of the strap.

b.   Tighten to desired fit.
c.   Lock strap in place by pulling beaded strap into the ta-

pered smaller opening of the beaded strap end. A distinct
snap noise should be heard once the strap is properly seat-
ed.

d.   Pull on the strap once locked in place to ensure beaded

strap is properly installed. This will prevent the drain hose
from dislodging from drain receptacle during use.

TLW2341N_SVG

4

5

3

2

1

1.  

Ribbed Portion of Drain Hose

2.  

Beaded Strap

3.  

Standpipe - 2 in. [51mm] or 1-1/2 in. [40 mm] Diameter

4.  

36 in. [914 mm] Recommended Height

5.  

12 in. [305 mm]

Figure 5

 Low Standpipe Installation

If standpipe is lower than 36 inches [914 mm], you must install
No. 562P3 Siphon Break Kit. This kit is available (as optional
equipment at extra cost) through an authorized dealer or parts dis-
tributor. Installation instructions are supplied with the kit.

TLW2283N_SVG

2

1

3

1.  

562P3 Siphon Break Kit

2.  

Standpipe

3.  

Drain Hose

Figure 6

 Wall Installation

Check wall drain height. The recommended height for the drain
is 36 inches [914 mm].

Install standpipe adapter onto drain hose only if standpipe diame-
ter is 2 inches [51 mm] or less.

For installations of this type, the drain hose MUST be secured to
one of the fill hoses using the beaded strap from accessories bag.
Refer to 

Figure 7 

.

W329I_SVG

2

1

1.  

Beaded Strap (tape if necessary)

2.  

Standpipe Adapter (select models)

Figure 7

Installation

©

 Copyright, Alliance Laundry Systems LLC -

 DO NOT COPY or TRANSMIT

  8

  Part No. 204871ENR1

Summary of Contents for TC5003WN

Page 1: ...ers Original Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machine www s...

Page 2: ......

Page 3: ...ation 7 Low Standpipe Installation 8 Wall Installation 8 Laundry Tub Installation 8 Position and Level the Washer 9 Plug In the Washer 9 Electrical Requirements 9 Earth Ground Instructions 10 Check Li...

Page 4: ...ic Control 41 25 in 1048 mm Knob Control 40 75 1035 mm D 53 in 1346 mm E 26 in 660 mm F 0 4 in 10 mm G 25 63 in 651 mm H 29 in 737 mm I 42 75 in 1086 mm J 36 in 914 mm With leveling legs turned into b...

Page 5: ...Hose Kit if needed Kit includes two fill hoses color coded for hot and cold water If using any other hoses follow these requirements Hoses must be new Hoses must be a minimum of 3 8 in inside diameter...

Page 6: ..._SVG Figure 3 Connect Fill Hoses WARNING Under certain conditions hydrogen gas may be pro duced in a hot water system that has not been used for two weeks or more HYDROGEN GAS IS EXPLO SIVE If the hot...

Page 7: ...tight Make sure the red color coded hose from the hot water faucet goes to the water mixing valve marked H and the blue color coded hose from the cold faucet goes to the valve marked C Refer to Figure...

Page 8: ...e TLW2341N_SVG 4 5 3 2 1 1 Ribbed Portion of Drain Hose 2 Beaded Strap 3 Standpipe 2 in 51mm or 1 1 2 in 40 mm Diameter 4 36 in 914 mm Recommended Height 5 12 in 305 mm Figure 5 Low Standpipe Installa...

Page 9: ...p and check if the washer is lev el from side to side and front to back 6 If washer is not level tilt washer back to access the front lev eling legs Loosen the locknuts and adjust legs by screwing int...

Page 10: ...e plugged directly into a polarized three slot effective earth ground receptacle rated 110 120 Volts AC alternating current 15 Amps Refer to Figure 11 to determine correct polarity of the wall recep t...

Page 11: ...m has an effective earth ground have a qualified electri cian or your local electrical utility company check it and cor rect any problems WARNING This unit is equipped with a three prong earth ground...

Page 12: ...TLW2281N_SVG1 6 Plug In the Washer TLW2289N_SVG CHECK CHECK 3 Connect Fill Hoses TLW1988N_SVG HOT COLD 7 Add Water to the Washer W391I_SVG CHECK CHECK 4 Connect Drain Hose to Drain Receptacle TLW2288...

Reviews: