Floor Layout and Pad Dimensions
Dimensional Clearances - Single Machine Mount - 20-60 Pound [9.1-27.2 Kg] Models (refer to
Table 11
)
CHM2504N_SVG
1
2
3
4
5
A
C
C
B
B
D
E
1.
Wall
2.
Rear Edge of Pad
3.
Side Edge of Pad
4.
Machine 1
5.
Front Edge of Pad
Figure 11
Dimensional Clearances - Single Machine Mount - 20-60 Pound [9.1-27.2 Kg] Models, in. [mm]
Description
20
30
40
60
A
Distance to wall (minimum)
24 [610]
24 [610]
24 [610]
24 [610]
B
Distance of machine base to
edge of pad (minimum)
3.44 [87]
4 [102]
3.99 [101]
5.99 [152]
C
Distance of machine base to
edge of pad (minimum)
2.52 [64]
2.51 [64]
2.81 [71]
5.18 [131]
D
Length of pad (minimum)
34.8 [884]
39.5 [1003]
43.5 [1105]
50.6 [1285]
Table 11