29
Installation
F232058
Steam Requirements
(Steam Heat Option Only)
For machines equipped with optional steam
heat, install piping in accordance with
approved commercial steam practices. Steam
requirements are shown in the table below.
Note:
Failure to install the supplied steam
filter may void the warranty.
Never touch internal or external steam
pipes, connections, or components. These
surfaces can be extremely hot and will
cause severe burns. The steam must be
turned off and the pipe, connections, and
components allowed to cool before the pipe
can be touched.
SW014
WARNING
Steam Supply Information
Steam inlet connection, in. (mm)
1/2 (DN13)
Number of steam inlets
1
Recommended pressure, psi (bar)
30 – 80 (2.0 – 5.5)
Maximum pressure, psi (bar)
80 (5.4)