![background image](http://html1.mh-extra.com/html/alliance-laundry-systems/ul24a118/ul24a118_installation-and-operation-manual_2901376029.webp)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Maintenance
27
1800000
Hydraulic Pressure Settings
To adjust hydraulic pressure:
1. Remove cap from side of hydraulic pump. Refer
2. Using a 4 mm Allen Wrench, adjust screw as
follows: turn clockwise (up) to increase hydraulic
pressure, turn counter clockwise (down) to
decrease hydraulic pressure.
3. Reinstall cap.
FWF98N
1
Cap
Figure 11
FWF98N
1
Baking
Starting
After 10 Days
PSI
Bar
PSI
Bar
PSI
Bar
508
35
290
20
363
25
Table 11
Summary of Contents for UL24A118
Page 2: ......